Temperature: 1400°C / 2552°F

1400 degree Celsius (°C) RESIDUE ANALYSIS FURNACE CHAMBER SIZE 225 x 450 x 225 MM

View in:
4.9 (14 ratings)
For Customized FURNACES & Thermal Equipments : Call / WhatsApp 91 8100640898
For Customized FURNACES & Thermal Equipments : Call / WhatsApp 91 8100640898
For Customized FURNACES & Thermal Equipments : Call / WhatsApp 91 8100640898
Base Price (Excl. GST)
₹205,237.19
+ Packaging: ₹5,460.97 (optional for factory/self pickup)
+ GST (18%): ₹36,942.69
* Shipping calculated at checkout
Est. Total (incl. GST + packaging): ₹247,640.85
units
Product Specifications
CategoryMuffle Furnace
ModelResidue Analysis Furnace
Max Temperature1400°C (2552°F)
Working Temperature1300°C
Thermocouple TypeB (Platinum-30% Rhodium)
Thermocouple Details200 to +1700°C range, High purity alumina insulation, Platinum-Rhodium alloy sheath, 8mm diameter, Type B, Tolerance Class 2
Heating ElementSilicon Carbide (SiC)
Element DetailsHigh power density, Brittle material, SiC heating elements, Max temp: 1600°C
Chamber (MM)225 x 450 x 225
Outer Body (MM)640.0 x 1065.0 x 500.0
Chamber Volume22.8 Litres
Volume (cu.ft)12.2 ft³
Power Load10.45 kW
Power Supply440V, Three Phase
Gross Weight110.91 kg
Chamber ShapeRectangular - tall
Customise Your Order
Body Material
Body Paint Type
Temperature Controller
Safety Device

About This 1400°C Residue Analysis Furnace 225 x 450 x 225 MM Chamber

This furnace is used in analytical laboratories to determine the residue content of a material, often by burning off the non-residue portion. Operating at temperatures like 600°C, it facilitates controlled combustion. The working principle involves igniting a weighed sample and heating it until only inorganic ash remains, which is then weighed. Its purpose is to measure the inorganic (mineral) content of fuels, foodstuffs, polymers, and lubricants, providing important quality and compliance data for industries like petroleum, food processing, and plastics manufacturing.

Trutherm manufactures 1400 Degree Celsius (°C) Residue Analysis Furnace 225 x 450 x 225 MM Chamber for buyers who search by exact machine type, chamber size and 1400°C temperature rating. This page is specific to the MM dimension version, so the chamber size is presented in the unit normally used in the buyer's drawing, tender or purchase request.

This configuration is suitable when the sample load must fit a 225 x 450 x 225 MM chamber with usable chamber volume of 22.8 litre, approximate power load of 10.2 kW, rectangular - tall chamber profile. It is commonly selected for laboratory, QC, metallurgical, ceramic, pharmaceutical and industrial heat-treatment work requiring stable heating and repeatable process conditions. Typical use includes general laboratory and industrial heat-treatment applications requiring stable, repeatable temperature control.

Equivalent chamber references: 225 x 450 x 225 MM, 23 x 45 x 23 CM and 9 x 18 x 9 INCH. Buyers searching for 1400°C Residue Analysis Furnace 225 x 450 x 225 MM; Residue Analysis Furnace 1400°C 225 x 450 x 225 MM; Residue Analysis Furnace 225 x 450 x 225 MM 1400°C; 225 x 450 x 225 MM 1400°C Residue Analysis Furnace; 1400 Degree Residue Analysis Furnace 225 x 450 x 225 MM; Residue Analysis Furnace 1400 Degree 225 x 450 x 225 MM can verify the same physical chamber on this canonical product page before requesting price, GST invoice, packaging and delivery.

A muffle furnace is usually the first furnace a lab installs, since it covers the broadest share of everyday heating, drying and ashing tasks before more specialised equipment is added.

A muffle furnace isolates the sample from direct contact with heating elements or combustion gases, giving cleaner, more repeatable results than an open flame or hot-plate process.

FAQs for 1400 Degree Celsius (°C) Residue Analysis Furnace 225 x 450 x 225 MM Chamber

What is Residue Analysis Furnace typically used for? Typical use includes general laboratory and industrial heat-treatment applications requiring stable, repeatable temperature control.
What is 1400 Degree Celsius (°C) Residue Analysis Furnace 225 x 450 x 225 MM Chamber best suited for? It is best suited for controlled heating jobs where this exact 225 x 450 x 225 MM chamber size must fit the sample, crucible, tray or batch volume.
Can Trutherm supply 1400 Degree Celsius (°C) Residue Analysis Furnace 225 x 450 x 225 MM Chamber with custom controls? Yes. Controller type, safety devices, body material, power connection and documentation can be configured according to application and site requirements.
Is this chamber size available in CM and INCH also? Yes. The same chamber is listed as 225 x 450 x 225 MM, 23 x 45 x 23 CM and 9 x 18 x 9 INCH so searches and purchase documents using any common dimension unit match this product.
How is pricing decided for 1400 Degree Celsius (°C) Residue Analysis Furnace 225 x 450 x 225 MM Chamber? Price depends on chamber size, temperature rating, insulation, heating element, controller, electrical load, packaging, GST and delivery requirements.

Application Examples

  • General laboratory heat treatment, drying and ashing across sample types.
  • Calcination and loss-on-ignition testing.
  • Small-batch annealing and stress-relieving of metal parts.
  • Teaching and demonstration use in institutional labs.

Industry Use-Cases

  • Multi-purpose QC and testing laboratories.
  • Educational institutions running heat-treatment demonstrations.
  • Small manufacturers needing an all-round furnace.
  • Research groups with varied, low-volume heating needs.

Recommended Accessories

Ceramic sample trays Spare K-type thermocouple Heat-resistant handling gloves PID controller upgrade

Why Choose This Residue Analysis Furnace

As a general-purpose muffle furnace, this model covers a broader range of routine heating tasks than a process-specific ashing, tube or sintering furnace, making it the practical default when the lab runs mixed sample types rather than one dedicated process.

Related Furnace Pages

1400 Degree Celsius Residue Analysis Furnace chamber sizes Residue Analysis Furnace 220 x 435 x 220 MM chamber Residue Analysis Furnace 435 x 220 x 220 MM chamber Residue Analysis Furnace 450 x 225 x 225 MM chamber Residue Analysis Furnace 235 x 245 x 400 MM chamber Residue Analysis Furnace manufacturer

Products You May Be Interested In

High Temperature Muffle Furnace
Muffle Furnace
High Temperature Muffle Furnace
Digital Precious Metal Furnace
Muffle Furnace
Digital Precious Metal Furnace
High-Temp Glass Melting Furnace
Muffle Furnace
High-Temp Glass Melting Furnace
Digital Furnace
Muffle Furnace
Digital Furnace
Laboratory Box Furnace
Muffle Furnace
Laboratory Box Furnace
Alloy Heat Treatment Furnace
Muffle Furnace
Alloy Heat Treatment Furnace