Web Analytics Made Easy - Statcounter
 +91 8100640898 (11 AM to 6 PM)    +91 9475747057
1200 degree Celsius (°C) Sulphur Furnace Chamber 670 x 670 x 870 MM / 67 x 67 x 87 CM / 26 x 26 x 34 INCH | Manufacturer India
This is a sample image
actual model may differ
Direct Manufacturer GST Invoice Pan-India Delivery
Temperature: 1200°C / 2192°F

1200 degree Celsius (°C) SULPHUR FURNACE CHAMBER SIZE 670 x 670 x 870 MM

View in:
4.9 (14 ratings)
For Customized FURNACES & Thermal Equipments : Call / WhatsApp 91 8100640898
For Customized FURNACES & Thermal Equipments : Call / WhatsApp 91 8100640898
For Customized FURNACES & Thermal Equipments : Call / WhatsApp 91 8100640898
Base Price (Excl. GST)
₹195,325.64
+ Packaging: ₹15,346.13 (optional for factory/self pickup)
+ GST (18%): ₹35,158.62
* Shipping calculated at checkout
Est. Total (incl. GST + packaging): ₹245,830.39
units
Product Specifications
CategoryMuffle Furnace
ModelSulphur Furnace
Max Temperature1200°C (2192°F)
Working Temperature1100°C
Thermocouple TypeS (Platinum-10% Rhodium)
Thermocouple DetailsType S, Tolerance Class 2, 0 to +1450°C range, High purity alumina insulation, Platinum sheath, 6mm diameter
Heating ElementKanthal A1 (FeCrAl)
Element DetailsFeCrAl alloy with rare earth elements, Max temp: 1425°C, Superior cyclic performance
Chamber (MM)670 x 670 x 870
Outer Body (MM)1075.0 x 1285.0 x 1155.0
Chamber Volume390.5 Litres
Volume (cu.ft)58.4 ft³
Power Load33.67 kW
Power Supply440V, Three Phase
Gross Weight454.26 kg
Chamber ShapeSquare
Customise Your Order
Body Material
Body Paint Type
Temperature Controller
Safety Device

About This 1200°C Sulphur Furnace 670 x 670 x 870 MM Chamber

An alternative spelling for Sulfur Furnace. This furnace is used for processes involving sulfur, such as in the Claus process for recovering sulfur from hydrogen sulfide gas or for testing sulfur content. Operating at temperatures around 1000°C, it facilitates the combustion or reaction of sulfur compounds. The working principle depends on the application but often involves controlled combustion and catalysis. Its purpose is in oil and gas refineries for sulfur recovery (an environmental imperative) and in analytical laboratories for determining sulfur in various materials.

This configuration is suitable when the sample load must fit a 670 x 670 x 870 MM chamber with usable chamber volume of 390.5 litre, approximate power load of 32.3 kW, square chamber profile. It is commonly selected for laboratory, QC, metallurgical, ceramic, pharmaceutical and industrial heat-treatment work requiring stable heating and repeatable process conditions. Typical use includes general laboratory and industrial heat-treatment applications requiring stable, repeatable temperature control.

Equivalent chamber references: 670 x 670 x 870 MM, 67 x 67 x 87 CM and 26 x 26 x 34 INCH. Buyers searching for 1200°C Sulphur Furnace 670 x 670 x 870 MM; Sulphur Furnace 1200°C 670 x 670 x 870 MM; Sulphur Furnace 670 x 670 x 870 MM 1200°C; 670 x 670 x 870 MM 1200°C Sulphur Furnace; 1200 Degree Sulphur Furnace 670 x 670 x 870 MM; Sulphur Furnace 1200 Degree 670 x 670 x 870 MM can verify the same physical chamber on this canonical product page before requesting price, GST invoice, packaging and delivery.

Trutherm manufactures 1200 Degree Celsius (°C) Sulphur Furnace 670 x 670 x 870 MM Chamber for buyers who search by exact machine type, chamber size and 1200°C temperature rating. This page is specific to the MM dimension version, so the chamber size is presented in the unit normally used in the buyer's drawing, tender or purchase request.

Because muffle furnaces are used across ashing, drying, calcination and light heat-treatment, the chamber and controller are specified for flexibility rather than one narrow process window.

Routine QC and teaching labs value a muffle furnace precisely because one unit can cover several standard test methods without dedicated process-specific tooling.

FAQs for 1200 Degree Celsius (°C) Sulphur Furnace 670 x 670 x 870 MM Chamber

How is pricing decided for 1200 Degree Celsius (°C) Sulphur Furnace 670 x 670 x 870 MM Chamber? Price depends on chamber size, temperature rating, insulation, heating element, controller, electrical load, packaging, GST and delivery requirements.
What is Sulphur Furnace typically used for? Typical use includes general laboratory and industrial heat-treatment applications requiring stable, repeatable temperature control.
What is 1200 Degree Celsius (°C) Sulphur Furnace 670 x 670 x 870 MM Chamber best suited for? It is best suited for controlled heating jobs where this exact 670 x 670 x 870 MM chamber size must fit the sample, crucible, tray or batch volume.
Can Trutherm supply 1200 Degree Celsius (°C) Sulphur Furnace 670 x 670 x 870 MM Chamber with custom controls? Yes. Controller type, safety devices, body material, power connection and documentation can be configured according to application and site requirements.
Is this chamber size available in CM and INCH also? Yes. The same chamber is listed as 670 x 670 x 870 MM, 67 x 67 x 87 CM and 26 x 26 x 34 INCH so searches and purchase documents using any common dimension unit match this product.

Application Examples

  • General laboratory heat treatment, drying and ashing across sample types.
  • Calcination and loss-on-ignition testing.
  • Small-batch annealing and stress-relieving of metal parts.
  • Teaching and demonstration use in institutional labs.

Industry Use-Cases

  • Multi-purpose QC and testing laboratories.
  • Educational institutions running heat-treatment demonstrations.
  • Small manufacturers needing an all-round furnace.
  • Research groups with varied, low-volume heating needs.

Recommended Accessories

Ceramic sample trays Spare K-type thermocouple Heat-resistant handling gloves PID controller upgrade

Why Choose This Sulphur Furnace

As a general-purpose muffle furnace, this model covers a broader range of routine heating tasks than a process-specific ashing, tube or sintering furnace, making it the practical default when the lab runs mixed sample types rather than one dedicated process.

Related Furnace Pages

1200 Degree Celsius Sulphur Furnace chamber sizes Sulphur Furnace 675 x 855 x 675 MM chamber Sulphur Furnace 855 x 675 x 675 MM chamber Sulphur Furnace 670 x 870 x 670 MM chamber Sulphur Furnace 870 x 670 x 670 MM chamber Sulphur Furnace manufacturer

Products You May Be Interested In

Box Furnace
Muffle Furnace
Box Furnace
Biscuit Firing Furnace
Muffle Furnace
Biscuit Firing Furnace
Gemstone Heat Treatment Furnace
Muffle Furnace
Gemstone Heat Treatment Furnace
High-Temp Dental Sintering Furnace
Muffle Furnace
High-Temp Dental Sintering Furnace
Carbonization Furnace
Muffle Furnace
Carbonization Furnace
Residue Analysis Furnace
Muffle Furnace
Residue Analysis Furnace