Web Analytics Made Easy - Statcounter
 +91 8100640898 (11 AM to 6 PM)    +91 9475747057
1200 degree Celsius (°C) Residue Analysis Furnace Chamber 100 x 100 x 100 MM / 10 x 10 x 10 CM / 4 x 4 x 4 INCH | Manufacturer India
This is a sample image
actual model may differ
Direct Manufacturer GST Invoice Pan-India Delivery
Temperature: 1200°C / 2192°F

1200 degree Celsius (°C) RESIDUE ANALYSIS FURNACE CHAMBER SIZE 100 x 100 x 100 MM

View in:
4.7 (25 ratings)
For Customized FURNACES & Thermal Equipments : Call / WhatsApp 91 8100640898
For Customized FURNACES & Thermal Equipments : Call / WhatsApp 91 8100640898
For Customized FURNACES & Thermal Equipments : Call / WhatsApp 91 8100640898
Base Price (Excl. GST)
₹18,815.40
+ Packaging: ₹2,684.37 (optional for factory/self pickup)
+ GST (18%): ₹3,386.77
* Shipping calculated at checkout
Est. Total (incl. GST + packaging): ₹24,886.54
units
Product Specifications
CategoryMuffle Furnace
ModelResidue Analysis Furnace
Max Temperature1200°C (2192°F)
Working Temperature1100°C
Thermocouple TypeS (Platinum-10% Rhodium)
Thermocouple Details0 to +1450°C range, High purity alumina insulation, Platinum sheath, 6mm diameter, Type S, Tolerance Class 2
Heating ElementKanthal A1 (FeCrAl)
Element DetailsSuperior cyclic performance, FeCrAl alloy with rare earth elements, Max temp: 1425°C
Chamber (MM)100 x 100 x 100
Outer Body (MM)510.0 x 700.0 x 375.0
Chamber Volume1 Litres
Volume (cu.ft)4.9 ft³
Power Load2.87 kW
Power Supply220V, Single Phase
Gross Weight35.42 kg
Chamber ShapeSquare
Customise Your Order
Body Material
Body Paint Type
Temperature Controller
Safety Device

About This 1200°C Residue Analysis Furnace 100 x 100 x 100 MM Chamber

This furnace is used in analytical laboratories to determine the residue content of a material, often by burning off the non-residue portion. Operating at temperatures like 600°C, it facilitates controlled combustion. The working principle involves igniting a weighed sample and heating it until only inorganic ash remains, which is then weighed. Its purpose is to measure the inorganic (mineral) content of fuels, foodstuffs, polymers, and lubricants, providing important quality and compliance data for industries like petroleum, food processing, and plastics manufacturing.

This configuration is suitable when the sample load must fit a 100 x 100 x 100 MM chamber with usable chamber volume of 1 litre, approximate power load of 2.9 kW, square chamber profile. It is commonly selected for laboratory, QC, metallurgical, ceramic, pharmaceutical and industrial heat-treatment work requiring stable heating and repeatable process conditions. Typical use includes general laboratory and industrial heat-treatment applications requiring stable, repeatable temperature control.

Equivalent chamber references: 100 x 100 x 100 MM, 10 x 10 x 10 CM and 4 x 4 x 4 INCH. Buyers searching for 1200°C Residue Analysis Furnace 100 x 100 x 100 MM; Residue Analysis Furnace 1200°C 100 x 100 x 100 MM; Residue Analysis Furnace 100 x 100 x 100 MM 1200°C; 100 x 100 x 100 MM 1200°C Residue Analysis Furnace; 1200 Degree Residue Analysis Furnace 100 x 100 x 100 MM; Residue Analysis Furnace 1200 Degree 100 x 100 x 100 MM can verify the same physical chamber on this canonical product page before requesting price, GST invoice, packaging and delivery.

Trutherm manufactures 1200 Degree Celsius (°C) Residue Analysis Furnace 100 x 100 x 100 MM Chamber for buyers who search by exact machine type, chamber size and 1200°C temperature rating. This page is specific to the MM dimension version, so the chamber size is presented in the unit normally used in the buyer's drawing, tender or purchase request.

A muffle furnace is usually the first furnace a lab installs, since it covers the broadest share of everyday heating, drying and ashing tasks before more specialised equipment is added.

A muffle furnace isolates the sample from direct contact with heating elements or combustion gases, giving cleaner, more repeatable results than an open flame or hot-plate process.

FAQs for 1200 Degree Celsius (°C) Residue Analysis Furnace 100 x 100 x 100 MM Chamber

What is 1200 Degree Celsius (°C) Residue Analysis Furnace 100 x 100 x 100 MM Chamber best suited for? It is best suited for controlled heating jobs where this exact 100 x 100 x 100 MM chamber size must fit the sample, crucible, tray or batch volume.
Can Trutherm supply 1200 Degree Celsius (°C) Residue Analysis Furnace 100 x 100 x 100 MM Chamber with custom controls? Yes. Controller type, safety devices, body material, power connection and documentation can be configured according to application and site requirements.
Is this chamber size available in CM and INCH also? Yes. The same chamber is listed as 100 x 100 x 100 MM, 10 x 10 x 10 CM and 4 x 4 x 4 INCH so searches and purchase documents using any common dimension unit match this product.
How is pricing decided for 1200 Degree Celsius (°C) Residue Analysis Furnace 100 x 100 x 100 MM Chamber? Price depends on chamber size, temperature rating, insulation, heating element, controller, electrical load, packaging, GST and delivery requirements.
What is Residue Analysis Furnace typically used for? Typical use includes general laboratory and industrial heat-treatment applications requiring stable, repeatable temperature control.

Application Examples

  • General laboratory heat treatment, drying and ashing across sample types.
  • Calcination and loss-on-ignition testing.
  • Small-batch annealing and stress-relieving of metal parts.
  • Teaching and demonstration use in institutional labs.

Industry Use-Cases

  • Multi-purpose QC and testing laboratories.
  • Educational institutions running heat-treatment demonstrations.
  • Small manufacturers needing an all-round furnace.
  • Research groups with varied, low-volume heating needs.

Recommended Accessories

Ceramic sample trays Spare K-type thermocouple Heat-resistant handling gloves PID controller upgrade

Why Choose This Residue Analysis Furnace

As a general-purpose muffle furnace, this model covers a broader range of routine heating tasks than a process-specific ashing, tube or sintering furnace, making it the practical default when the lab runs mixed sample types rather than one dedicated process.

Related Furnace Pages

Residue Analysis Furnace 900 x 900 x 900 MM chamber Residue Analysis Furnace 90 x 115 x 110 MM chamber Residue Analysis Furnace 90 x 110 x 115 MM chamber Residue Analysis Furnace manufacturer 1200 Degree Celsius Residue Analysis Furnace chamber sizes Residue Analysis Furnace 450 x 450 x 900 MM chamber

Products You May Be Interested In

Pyrolysis Furnace
Muffle Furnace
Pyrolysis Furnace
Gold Alloy Furnace
Muffle Furnace
Gold Alloy Furnace
Loss on Ignition Furnace
Muffle Furnace
Loss on Ignition Furnace
Ash Fusion Furnace
Muffle Furnace
Ash Fusion Furnace
Dental Melting Furnace
Muffle Furnace
Dental Melting Furnace
Residue Furnace
Muffle Furnace
Residue Furnace